Extractor hood faults we are called to in Belmont

Extractor hood with the fault locations numbered12345
Extractor hood drawing. The numbers match the faults listed alongside.
  1. 1Loud or rattling

    Likely cause. A fan wheel fouling its housing, or worn motor bearings.

    What you can check. Check the filters are clipped in. Loose filters rattle.

    What we do. We refit or replace the fan and motor.

  2. 2Lights do not work

    Likely cause. Blown lamps, a failed transformer or LED driver, or a bad switch.

    What you can check. Try a new lamp of the same type and wattage.

    What we do. We test the lighting circuit and replace the driver or switch.

  3. 3Poor suction although the fan runs

    Likely cause. Clogged filters, saturated carbon filters or a crushed duct.

    What you can check. Hold a sheet of kitchen paper to the filter. It should cling at top speed.

    What we do. We check the duct run and non-return flap and advise on filters.

  4. 4Stuck on one speed

    Likely cause. A failed speed switch or control board relay.

    What you can check. Switch off at the wall for a minute to reset the control.

    What we do. We replace the switch or board.

  5. 5Water drips from the hood

    Likely cause. Condensation running back down a long cold duct.

    What you can check. Leave the hood running for ten minutes after cooking.

    What we do. We check the duct fall and flap and suggest a remedy.

By make

Also in Belmont

Nearby

More about extractor hood repairs

Questions we are asked

Which days do you visit Belmont?

Engineer visits run Monday to Thursday. Ring 0208 462 2111 with your postcode and we will give you the first available day for Belmont.

How often should carbon filters be changed?

Every four to six months with regular cooking. They cannot be washed.

Can you replace an extractor motor?

Yes, where the maker still supplies it. Bring the model number and we will check before the visit.

Book a repair visit

Tell us the make, the model and what the appliance is doing. An engineer visits, finds the fault and agrees the price with you before repairing it.